net.server_select: Don't limit max file descriptor number on Windows.
--- a/net/server_select.lua Mon Apr 29 14:01:19 2013 +0200
+++ b/net/server_select.lua Mon Apr 29 20:26:48 2013 +0500
@@ -149,7 +149,8 @@
_sendtimeout = 60000 -- allowed send idle time in secs
_readtimeout = 6 * 60 * 60 -- allowed read idle time in secs
-_maxfd = luasocket._SETSIZE or 1024 -- We should ignore this on Windows. Perhaps by simply setting it to math.huge or something.
+local is_windows = package.config:sub(1,1) == "\\" -- check the directory separator, to detemine whether this is Windows
+_maxfd = luasocket._SETSIZE or (is_windows and math.huge) or 1024 -- max fd number, limit to 1024 by default to prevent glibc buffer overflow, but not on Windows
_maxselectlen = luasocket._SETSIZE or 1024 -- But this still applies on Windows
_maxsslhandshake = 30 -- max handshake round-trips